The is the basis of the HyperFlow-UIVK Automated Data Collection System used with lower level (controlled points). It provides for the collection, processing and reporting of data on the current gas flow and physical properties of natural gas at gas distribution stations.
Hyperflow-UIVK provides for:
  • the continuous monitoring of the operability of connected equipment;
  • adapting instrumentation and control equipment connections to different communication protocols;
  • the transmission of information about the measured medium’s physical properties to connected flowmeters, when chromatographs or densimeters are connected;
  • the archiving of readings from all connected instruments for the entire period of operation, and the transmission of current readings and archived data via GSM, hard-wired connection or Ethernet.

Signature features:

Touch screen control
Access to control functions for five users
Support for up to five users with individual passwords for access to control functions
Multiple modes of data transfer
Data transfer to the upper level via GSM and hard-wired connections
Standard communication protocols
The Hyperflow-UIVK uses standard communication protocols: MODBUS RTU and MODBUS TCP
Data security
Cryptographic protection for data transfer over unsecured channels
Verification of measurement and calculation parameter range
Data archive depth: 365 days

Characteristics

Multiple connection for gas flow (volume) measurement instruments
up to 16 instruments
Multiple analog inputs
up to 10 channels for receiving measurement information via 0...20 mA
Multiple inputs for temperature measurement
up to 6 platinum resistance thermometers
Analog outputs
up to 4 channels for transmitting data via 0...20 mA
Digital inputs
16 digital inputs
Digital outputs
16 digital inputs
Data transfer channels
2-MODBUS RTU, 2-HART
Frequency input
2 channels, input signal ranges from 0.1 to 10 kHz, the peak-to-peak amplitude is 3.5 to 30 V
Pulse input
2 channels, pulse counting input signal ranges from 0 to 100 kHz, with peak-to-peak amplitude of 3.5 to 30 V
Digital interfaces for connecting peripheral equipment
RS-232 / RS-485 with galvanic isolation (for connecting external devices) - 4
RS-232 (for connecting external devices) - 5
RS-485 (for connecting plug-in modules) - 1
RS-232 (for connecting plug-in modules) - 1
Power supply voltage
20 to 30 VDC
Structural design
Closed metal cabinet for wall mounting or crate for mounting in a 19-inch rack
Explosion protection marking
[Exib]IIA X
Ingress protection in accordance with GOST 14254-96:
Metal cabinet
IP54
Rack-mount crate for mounting in a 19-inch rack
IP20
Ambient temperature range
-20 to +50°C
Weight
not more than 12 kg
show all Characteristics

Compatible hardware:

The HyperFlow-UIVK is compatible with the following types of equipment:

  • HyperFlow-3Pm compound sensors with a flow calculation unit
  • HyperFlow and Vympel series ultrasonic flow meters
  • Superflow series flow calculation units
  • SG-16 (SG-16M) gas volume flow meters
  • EK series gas volume corrector
  • CONG-Prima series dew point transducers
  • CONG-Prima and Hygrovision series dew point analyzers
  • DANI PGC 90.50, MAG, Siemens Microsam or HROMOS UGS-1000 in-line chromatographs
  • Sensors with current output of 4-20 mA
  • Sensors with frequency output
  • Sensors with digital output
  • Temperature sensors (TSM 9418, TSP 9418 resistance thermometers)
  • IBP-002 uninterruptible power supply
  • Other equipment with RS-232 or RS-485 interfaces
The total number of gas flow metering instruments connected to the HyperFlow-UIVK is not to exceed 16.

HyperFlow-MK

Mini-communicator